Transapical Mitral Implantation of the Tiara Bioprosthesis Pre-Clinical Results Article

Full Text via DOI: 10.1016/j.jcin.2013.10.009 PMID: 24556094 Web of Science: 000331719900011
International Collaboration

Cited authors

  • Banai, Shmuel; Verheye, Stefan; Cheung, Anson; Schwartz, Marc; Marko, Alexei; Lane, Randy; Jolicoeur, E. Marc; Garceau, Patrick; Biner, Simon; Tanguay, Jean-Francois; Edelman, Elazer R.; White, Christopher J.

Abstract

  • Objectives This study sought to describe the pre-clinical evaluation of transapical mitral implantation of the Tiara (Neovasc Inc, Vancouver, British Columbia, Canada) valve in preparation for first-in-man implantation.; Background The Tiara is a transcatheter self-expanding mitral bioprosthesis, specifically designed for the complex anatomic configuration of the mitral apparatus. Methods Tiara valves were implanted in a short-term porcine model, in a long-term ovine model, and in human cadavers.; Results Short-term and long-term evaluation demonstrated excellent function and alignment of the valves, with no left ventricular outflow tract obstruction, coronary artery obstruction, or transvalvular gradients. Long-term evaluation of 7 sheep demonstrated clinically stable animals. A mild degree of prosthetic valve regurgitation was seen in 2 of the 7 sheep. A mild-to-moderate degree of paravalvular leak, which was attributed to this animal model, was observed in 6 of these animals. Cardioscopy and macroscopic evaluation demonstrated stable and secure positioning of the Tiara valve with no evidence of injury to the ventricular or atrial walls. Pericardial leaflets were free and mobile without calcifications. Implantation of the Tiara valves in human cadaver hearts demonstrated, upon visual inspection, proper anatomic alignment and seating of the valve, both at the atrial and at the ventricular aspects of the native mitral apparatus.; Conclusions In preparation for the first-in-man transcatheter mitral valve implantation, we report the successful pre-clinical evaluation of the Tiara transcatheter self-expanding mitral bioprosthetic valve. In porcine and ovine models without mitral regurgitation, transapical mitral implantation of the Tiara valve is technically feasible and safe, and results in a stable and well-functioning mitral bioprosthesis. (C) 2014 by the American College of Cardiology Foundation

Publication date

  • 2014

Published in

International Standard Serial Number (ISSN)

  • 1936-8798

Start page

  • 154

End page

  • 162

Volume

  • 7

Issue

  • 2